| 加工定制:否 | 品牌:YOKOGAWA/横河 | 型号:AAM11 |
| 用途:· | 产品认证:· |
项目特定网络阳离子
模型AAM11,AAM11B
输入信号
0至10 V DC 0至20 mA DC(* 1)(* 2)
(这是可能的,以将电力提供给发射机。)
输入电阻上电时1MΩ(100kΩ的在电源关闭后)250Ω
允许输入电压/电流-10至30 V DC40毫安DC或***
供电变送器
- 25.0〜25.5 V DC(输出电流限制:60毫安DC
或更少)
辅助电压输出1〜5 V DC;输出电阻:1Ω或***;
允许负载电阻:10kΩ或以上;信号地线与系统共享
开方***是否使用开方。
精度输入电压:±4 mV的;电流输入:±16μA;辅助电压输出:±12 mV的
影响环境温度变化10℃的变化:
电压输入:±4毫伏的特定连接的ED值+±0.15%
电流输入:±32μA
辅助电压输出:±24 mV的
数据更新周期50毫秒
电流消耗300毫安以下(5.0 V DC)
信号隔离器输入信号系统之间的隔离
耐压:1500 V AC /分钟
安装方式安装在I / O模块巢
如何连接连接到I / O模块鸟巢与M4螺钉端子
如何将输入信号是特定网络版***的输入信号,范围可通过软件设置。
* 1:该模块可与MTL屏障728在这种情况下结合时,布线电阻必须为10Ω或更少和2线式传送器的最小工作电压必须为12 V DC或更小。
* 2:当AAM11的电源关闭或异常情况发生时,电流输入回路是开放的。
不要与其它接收器共用的电流信号。要共享的信号,连接分流电阻(250Ω)电流输出模块将与共享电压输出。
Items | Specifications | |
Model | AAM11, AAM11B | |
Input signal |
0 to 10 V DC | 0 to 20 mA DC (*1) (*2) (It is possible to supply power to a transmitter.) |
Input resistance | 1 MΩ at power-up (100 kΩ at power-down) | 250 Ω |
Allowable input voltage/current | -10 to 30 V DC | 40 mA DC or less |
Supplying power to transmitter |
- | 25.0 to 25.5 V DC (Output current limit: 60 mA DC or less ) |
Auxiliary voltage output | 1 to 5 V DC; Output resistance: 1 Ω or less; Allowable load resistance: 10 kΩ or more; Signal ground is shared with system | |
Square root extraction | Specify whether to use square root extraction. | |
Accuracy | Voltage input: ±4 mV; Current input: ±16 µA; Auxiliary voltage output: ±12 mV | |
Effect of ambient temperature change | For 10°C change: Voltage input: ±4 mV + ± 0.15 % of specified value Current input: ±32 µA Auxiliary voltage output: ±24 mV | |
Data update period | 50 ms | |
Current consumption | 300 mA or less (5.0 V DC) | |
Signal ***lation | Input signals are ***lated between systems Withstanding voltage: 1500 V AC/min | |
How installed | Installed in the I/O Module Nest | |
How connected | Connected to the terminals of the I/O Module Nest with M4 screws | |
How input signals are specified | Specify input signals and range by software setting. | |
*1: This module can be combined with MTL barrier 728. In this case, wiring resistance must be 10 Ω or less and the minimum operating voltage of the 2-wire transmitter must be 12 V DC or less.
*2: When the power of AAM11 is OFF or an abnormal condition occurs, the current input loop is open.
Do not share current signals with other receivers. To share signal, attach Shunt Resistance (250 Ω) to current-output mod- ule and share voltage output.