广州乘方自动化设备有限公司
  • 资质核验已核验企业营业执照
  • 所 在 地:广东 广州 黄埔区
  • 主营产品: 工控自动化仪表 PH/ORP分析 气相色谱仪及配件 DCS控制系统模
8年
  • 资质核验已核验企业营业执照
当前位置:
首页>
供应产品>
横河SR20-AP24电极传感器
微信联系
扫一扫
添加商家微信
电话洽谈 在线咨询

横河SR20-AP24电极传感器

价    格

订货量

  • 面议 价格为商家提供的参考价,请通过"获取最低报价"
    获得您最满意的心理价位~

    不限

黄女士
邮箱已验证
手机已验证
微信已验证
177 0199 3477 020-17701993477 查看联系方式
微信在线
  • 发货地:广东 广州
  • 发货期限:不限
  • 供货总量: 99件
广州乘方自动化设备有限公司 VIP会员 第8年
  • 资质核验已核验企业营业执照
  • 黄女士
    邮箱已验证
    手机已验证
    微信已验证
  • 177 0199 3477
  • 微信交谈
    扫一扫 微信联系
  • 广东 广州
  • 工控自动化仪表,PH/ORP分析,气相色谱仪及配件,DCS控制系统模

联系方式

  • 联系人:
    黄女士
  • 职   位:
    经理
  • 电   话:
    020-17701993477
  • 手   机:
    17701993477
  • 地   址:
    广东 广州 黄埔区 神舟路绿地智慧广场二期D栋2418室
加工定制:否品牌:日本横河YOKOGAWA型号:SR20-AP24
种类:电学制作工艺:·输出信号:·

General

The principle of pHmeasurement is quite simple. All one needs is aglass electrodeconstructed of pH sensitive glass and a reference (potential) that remains stable under all conditions.This directly shows the weak point inthe measuring loop. As the reference needs an ‘open’ circuit to the process, a stable reference potential is sometimes hard to keep. Mostreference electrodes have aporous diaphragm to realize this open

connection to the process. Several materials are being used like ceramic, Zirconia, PTFE and wood. The porous diaphragm can

get clogged or high diffusion potentials may build up.Po***ning of the reference is another cause for unstable reference potentials.

A reference electrodecan be po***ned by the penetration of

the process liquid or by diffusion of components of the process medium through the diaphragm. Thestable reference potential which is formed by a Ag/AgCl referencesystem in aKCl solution is shifted if either gets effected.E.g. silver chloride +sulfide will form the insoluble silver sulfide. These particles give deposits, which canblock the diaphragm from inside the reference electrode.Likewise the chloride concentration can be altered and therefore thereference potentialis altered. The latter can be corrected by re-calibration. Po***ningof the AgCl referencesystem is irreversible and the reference electrodeneeds to be replaced.

 

Maintenance

For accuratepH measurement, regular (even frequent)

maintenance is required.This knowledge is decisive for the


selection of fittings and electrodes of the pHmeasuring loop. One needs to keep in mind that the electrode(s) must remain accessible and exchangeable. Once the right fitting has been selected, the process of selecting the right electrode(s) must take place.

 

Glass electrode

The SM21-AG4 will suit the great majority of the pH applications as this electrode is constructed in such a way that its sensitivity and strength are optimized. When sensitivity isrequired more than strength than the SM21-AG2should be selected.

For toughindustrial applications (including auto-cleaning) thedome shaped electrode is the best selection. ‘L’-glass should be selected when the electrode is used at higher temperatures (>70ºC) and/or in applications that need a glass type that isresistant to chemical attack.

 

Reference electrode

Reference electrodes come in flowing- and non-flowing types.Flowing types such as the SR20-AC52, AC32 with a ceramic diaphragm are used in processes that have low ionic strength such as (ultra) pure water. The SR20-AS52 is aflowing type electrode with asleeve junction.Due to the high electrolyte flow rate, the sensor is suitable for UPW application as well as in highly polluting applications. The electrolyte flow towards the processtends to keep the junction clean from clogging and po***ning.

For all other applications the SR20-AP24 is preferred.When the process cannot withstand KCl, the SR20-AP26 should be


产品推荐
  • 面议
  • 面议
  • 面议
  • 面议
  • 面议
免责声明:
本页面所展现的公司信息、产品信息及其他相关信息,均来源于其对应的商铺,信息的真实性、准确性和合法性由该信息来源商铺的所属发布者完全负责。部分产品内容可能由AI辅助生成,请以商家确认信息为准,供应商网对此不承担任何保证责任。
友情提醒:
建议您在购买相关产品前务必确认供应商资质及产品质量,过低的价格有可能是虚假信息,请谨慎对待,谨防欺诈行为。
 
建议您在搜索产品时,优先选择带有或标识的会员,该为供应商网VIP会员标识,信誉度更高。

版权所有 供应商网(www.gys.cn)

京ICP备2023035610号-2

广州乘方自动化设备有限公司 手机:17701993477 电话:020-17701993477 地址:广东 广州 黄埔区 神舟路绿地智慧广场二期D栋2418室